Weigh Scale Blender Communications
The Maguire Weigh Scale Blenders are capable of two-way
communications for enhanced control and data collection. The Maguire
Weigh Scale Blender's Controller itself uses Maguire's MLAN Protocol to send
and receive data through commands within the protocol. All Maguire
Controllers use RS-232 (MLAN) or Ethernet for communications. Our
12-12 Controller has Ethernet onboard while older Maguire Controllers can
utilize an Ethernet to Serial Converter. See the
Weigh Scale Blender's manual for communication port details.
Several options are available for methods of communication, all of which use
the MLAN Protocol.
Communication options are:
| Gravimetric Gateway™
Server (G2 Server) |
Read More |
| OPC - Object Linking and
Embedding (OLE) for Process Control |
Read More |
| Direct MLAN Protocol |
Read More |
Gravimetric Gateway™
Server (G2 Server)
The Gravimetric Gateway Server also referred to as
the G2 Server, is the name we give to the server software written
exclusively for the MAGUIRE Weigh Scale Blenders. The G2 Server enables
you to communicate directly from the server with one or more WSB
controllers or connect remotely from anywhere over a TCP/IP network using
the Gravimetric Gateway™
Client Software. The Gravimetric Gateway™
Server provides two-way communication between the server and the MLAN
network of blenders through downloading and constant retrieval of
information from WSB controllers. The Gravimetric Gateway™
software was designed to work as a stand-alone application to provide
enhanced reports and control. The Gravimetric Gateway™
software has the ability to use MySQL for it's databases.
The full version of the Gravimetric Gateway™
Server/Client Software is available for download here on the web site.
This full version software is limited to running as a demo package and/or
as G2 Lite which offers support for a single Maguire Blender. In this free
download, extrusion control is not available. To unlock the full potential
of this G2 software package , including extrusion control, a security key
is required and is available from Maguire Products. To download the latest
full version, follow
this link or call Maguire Products for
more information about G2.
Download the G2 Software Here.
OPC - Object Linking
and Embedding (OLE) for Process Control
OPC is a worldwide standard of application interface
in industrial automation software and the enterprise systems that support
industry. Maguire Products has worked closely with the following OPC
Server developers to provide OPC profiles to work directly with our Weigh
Scale Blenders. If you are interested in using OPC, please contact
the following companies to discuss Maguire Weigh Scale Blender
communications. All transactions and support for OPC are through the
OPC Developer company.
OPC Providers
Dimension Software Inc.
1536 St. Clair Road
Taylorsville, NC 28681
PH: 828-635-7189
Web Page:
http://www10.caro.net/dsi/
Contact: Shawn Overcash
Email: dsi1@caro.net
Product:
http://www10.caro.net/dsi/dsi_uws.htm
Read the Dimension Software Data Sheet
Download the Maguire / Dimension Software OPC
Profile (Requires the
Dimension Software OPC Server)
Kepware Technologies
400 Congress Street, 3rd Floor
Portland, ME 04101
PH: 207-775-1660
Web Page:
www.kepware.com
Product:
http://www.kepware.com/Products/products_u-conprotocolserver.htm
Read the Kepware Data Sheet
Download the Maguire / Kepware OPC Profile
(Requires the Kepware OPC Server)
Software Toolbox
148A East Charles Street
Matthews, North Carolina, 28105
PH: 704-849-2773
Web Page:
http://www.softwaretoolbox.com
Product:
http://www.softwaretoolbox.com/omniserver/
Download the Maguire / Software Toolbox OPC Profile
(Requires the Software Toolbox OPC
Server)
MLAN
Protocol
The MLAN Protocol (Maguire Local Area Network) is a
protocol consisting of commands that allows two-way communications to the
Maguire Weigh Scale Blenders. All Maguire Weigh Scale Blenders dated
back to 1992 contain the essential MLAN commands for basic control and
data collection while newer Maguire controllers contain additional
commands for enhanced control and data collection. The MLAN
Protocol was initially intended to provide information for individuals who
are writing software for Programmable Logic Controllers (PLCs) and needed
to communicate with the Maguire Weigh Scale Blender. This
protocol is the method used by our G2 Software as well as the OPC profiles
written for the OPC servers listed above. The Protocol is available
for free and is explained in detail in our
MLAN Protocol Manual. Customers who
wish to write their own software to communicate directly with the Maguire
Weigh Scale Blenders will need the
MLAN Protocol Manual. For a
complete understanding of the operation of the Weigh Scale Blender (WSB),
it is recommended that you have the four and/or twelve component
controller manual(s) available as a reference.
MLAN Protocol Manual
Other Maguire Manuals are Here
For more information on Weigh Scale Blender
communications please contact Maguire
Products Inc.
Maguire Products Inc.
11 Crozerville Road
Aston, PA 19014
(610) 459-4300
Fax: (610) 459-2700
info@maguire.com
|