Maguire Products Inc. Leading the Plastics Industry in: Weigh Scale Blenders, Pumps, Feeders, Loaders, Granulator, MLAN SoftwareMaguire Products Inc. Leading the Plastics Industry in: Weigh Scale Blenders, Pumps, Feeders, Loaders, Granulator, MLAN Software
  Home
  Manuals
  Technical Support
  Brochures
  Contact Us
  Request A Quote
Products
osspace
 Blenders
    Blender Manuals
    MicroBlender
    100 Series
    200 Series
    400 Series
    900 Series
    1800 Series
    MaxiBatch
    LineMaster™
    Dispensers
    VTA Stands
    AWS Stands
    Clear-Vu Hopper
    Blender Acces.
    Communications
  Dryers
      Dryer Manuals
      LPD-30
      LPD-100
      LPD-200
      LPD-1000
      Dryer Acces.
  Loaders
      Loader Manuals
      Clear-Vu Systems
      MLS Controller
      Venturi Systems
      Loader Acces.
  Feeders
      Feeder Manuals
      Series MCF
      Series MLG
      Series MPF
      Series MRF
      Series MSF
      Feeder Acces.
  Pumps
      Pump Manuals
      MPA Peristaltic
      MDA Drum Pumps
      MPM Pre-Mixers
      Pump Acces.
  G2 Communications
      Overview
      Screenshots
      G2 Manuals
      Downloads
      Troubleshooting
About Us
  About Us
  Maguire in the News
  Warranty
  Marketing
  space
  Gravimetric Blenders
  space2
  Login
G2 Communications Downloads
   

Gravimetric Gateway® Server (G2 Server)

The full version of the Gravimetric Gateway® Server/Client Software is available for download here on the web site.   This full version software is limited to running as a demo package and/or as G2 Lite which offers support for a single Maguire Blender.  In this free download, extrusion control is not available.  To unlock the full potential of this G2 software package , including extrusion control, a security key is required and is available from Maguire Products. To download the latest full version, click the button above.

G2 Release Notes 

If you are upgrading G2 from a previous version, please review the release notes before upgrading.  If you are currently using Security in G2, review the important information regarding changes to security in the release notes.

 
Important notice regarding Weigh Scale Blender chip versions and the G2 Software:

It was found that Twelve software chips within the Maguire controller released between December 03, 2004 and July 12, 2005 (controller will display v=D1203L through v= E0712L) have a bug that affects downloading recipe from the G2 software to the blender. If a recipe is sent to the controller from G2 during the time the blender is cycling, the new recipe components can be shifted up one component in the controller.  The problem is in blender software. We suggest anyone using G2 and twelve software controllers with a chip date code between December 03, 2004 and July 12, 2005 should update to the latest chip version.  To read how you can decode your chip version read this.  Please contact Maguire Products to arrange for a chip replacements. 

Gravimetric Gateway® (G2)  
Currently Available Downloads
Available Full Version 4.0.11 Download G2 Full Version
Available Update Version
At this time, updates require the download and install of the full version.  To update, simply install over your existing installation of G2.

Restrictions on G2 Upgrades:
In some cases G2 may be upgraded by simply updating a single JAR file. Before attempting to upgrade G2 through the Upgrade Only process, review the G2 Release Notes to see if your version of G2 qualifies for a G2 Upgrade Only.  If your version of G2 does not qualify for an upgrade using the single file upgrade, you must install the Full Version to upgrade to the latest version of G2.  See additional notes on upgrading 
Click Here

4.0.11

Download G2 Upgrade Only
 

G2 and MySQL®

Customers using MySQL with G2 who would like to upgrade to G2 version 4.0.5 and later must upgrade MySQL to version 4.1.x.  For more information on upgrading MySQL, please read the chapter, Upgrading MySQL on Windows in the MySQL Reference Manual http://dev.mysql.com/doc/
 

Hardware and Operating System Requirements
Hardware and Operating System Requirements for the installation of the G2 Server and/or the G2 Client Software

Computer System
IBM-PC or Compatible (Pentium III 600 or faster). We recommend that the G2 Server computer be dedicated to the purpose of collecting data for G2. Constant COM port communication between the G2 Server and the Maguire Weigh Scale Blenders may cause a noticeable lag in the processor when using the G2 Server computer for additional functions while the G2 Server is collecting data.  Also note that if you are using Ethernet for blender communications to 25 or more blenders, demand on the computer system may require a system faster than stated above.  In the case of Ethernet connected blenders totaling 25 or more, we recommend a minimum system of a Pentium III 1 GHz with 512 MB of RAM.

Operating System Requirements
G2 Server - Windows based platforms.  Recommended Windows Operating Systems: NT/2000/XP/VISTA
G2 Clients - Windows based platforms (95/98/ME/NT/2000/XP/VISTA)
(Windows 95/98/ME not recommended for G2 Server)

Minimal HD Space
6 Gigabyte Hard Drive or larger for long term data collection
Video
Super VGA 1024 x 768 resolution recommended, 800 x 600 acceptable
Memory
Minumum 256 MB
Ports
2 available serial ports (1 port for mouse if no PS2 port available, 1 port for MLAN), 1 available printer port
Mouse
PS2 preferable

Full Version Install Instructions

G2 Server / Client Installations for Windows
G2 Server - Windows based platforms.  Recommended Windows Operating Systems: NT/2000/XP/VISTA
G2 Clients - Windows based platforms (95/98/ME/NT/2000/XP/VISTA)
(Windows 95/98/ME not recommended for G2 Server)

Follow these instructions to install the Gravimetric Gateway® software.

Download Install
When you download the full G2 install you will save the file somewhere on your computer. A good place to save this file when you download it is on your desktop where it may be easily found when you are ready to install G2. After downloading the G2 Full Installation program, close all other programs including the Gravimetric Gateway® Server / Client Software if you are upgrading. Click your Start Button and choose Run. Browser your computer to the location of the file g2setup.exe and double-click on g2setup.exe. Click OK. The self-extracting zip file will prompt you for a destination directory to unzip into. By default this directory is c:g2temp. Click Finish to extract the install program. Click Yes to creating the G2temp directory. Click OK after extraction. Click Ok. Proceed to step 1 below.

CD-ROM Install
When the G2 CD-ROM is inserted into the CD-ROM drive the installation of the G2 Server should automatically start. If, however, it does not auto start, and you would like to install the G2 Server/Client Software, follow these steps:

Click the start button and choose "Run". Type the following replacing CDROM with your CD-ROM's drive letter: "CDROM:setup.bat" to install the Server/Client software. Click "OK". Proceed to step 1 below. 

  1. Select your language for the installation. Selecting the language will also default G2 to starting with this language.
  2. Read the welcome message and click Next.
  3. Choose the destination folder that G2 will be installed in. By default the directory is c:g2. To change the directory, click Browse. After selecting the folder, click next.
  4. Choose your system setup. Each part of the G2 Software may be selected independently. Choices are Server, Client, Satellite ComServer and Demo. After making your selections choose Next.
  5. Select your data directory. By default this location is C:g2g2data. This may be changed if necessary. Click Next.
  6. Select your computer's operating system and click Next.
  7. You may choose or create the Program folder in the start menu that G2 will appear in. By default that folder is Gravimetric Gateway. Click Next. The G2 program will now install.
  8. Click Finish.
  9. If you have installed the G2 Client/Server for the first time, please proceed to section VII,G2 Server Operation for Windows, in the G2 Manual.
      
  10. If you are upgrading with a full install of G2 and want to use your existing databases, copy all database files EXCEPT "language.data" and "language.key" from the original database location (by default, c:g2data for version 1.2.x) to the new location, c:g2g2data by default. An installation of a current G2 installation over an existing 2.0.x or later will use the same default location of the G2 databases (c:g2g2data) and will not be overwritten by the new installation.

To read more about the operation of the Gravimetric Gateway® Server for Windows 95/98/NT/2000/ME please read the G2 manual, available for download here.

Also review the Gravimetric Gateway® TCP/IP Requirements available for download here.

For important information on Time Zone requirements for G2 computers, click here.

G2 Update Instructions

IMPORTANT G2 VERSION UPGRADE NOTES:
To find out the version of G2 see the About Box in the help menu of the G2 Client. To find out what version of G2 is currently available, review the Release Notes.

The Gravimetric Gateway® Server / Client Software may be updated to the latest version easily and free of charge. G2 Updates may be obtained here online or requested on disk.

Depending on your version G2, it may or may not qualify for a single file download to update the Gravimetric Gateway® Software.  To determine if your G2 software may be updated to the current version through a single file download, compare your version to the currently available version as specified in the release notes.  If your first two numbers match the currently available version, you may use the Upgrade Only. Read the SINGLE FILE UPGRADE instructions below if your version of G2 can be upgraded without a full install.  If they do not match then you must use the G2 Full Install to upgrade G2. Read the FULL INSTALL / FULL UPGRADE instructions above.

SINGLE FILE UPGRADE

The Gravimetric Gateway® Server / Client Software may be updated to the latest version easily and free of charge.

If your G2 version qualifies for the single file upgrade then updating to the latest G2 version requires only that the g2.jar file be replaced. The most recent g2.jar file is available here online and can be obtained by clicking the Upgrade Only button above.

The single file update is downloaded as a self-extracting zip file called g2_update.exe.  

After downloading follow these simple steps:

  1. Close the Gravimetric Gateway® Server / Client Software.
      
  2. Make a backup of the existing g2.jar file located in the software directory by default is c:g2.
      
  3. Double-click the file "g2_update.exe".  The self-extracting zip file will prompt you for a destination directory which is the location where G2 was installed on your computer. By default, that location is "c:g2".  If the directory that the G2 software was installed in is different than the default directory, specify that directory instead.  Click Finish.  You will be prompted to over-write the existing g2.jar file.  Click yes.  Click ok.  If you were not prompted to over-write existing files this may indicate that G2 was not installed in the default directory location.  To verify that G2 was updated click "Help" then "About" in the G2 Client and verify that the version is the same as the update version.

Language File Update (If Available)

For G2 Version 2.0 or later only.  May not be available. 

The language file update is downloaded as a self-extracting zip file called "lang_update.exe".  

After downloading follow these simple steps:

  1. Close the Gravimetric Gateway® Server / Client Software.
      
  2. Make a backup of the existing language files (2 files) located in the G2 database directory (by default is c:g2g2data).
      
  3. Double-click the file "lang_update.exe".  The self-extracting zip file will prompt you for a destination directory which is the location where the G2 databases are located on your computer. By default, that location is "c:g2g2data".  If the directory that the G2 databases are located in is different than the default directory, specify that directory instead.  Click Finish.  You will be prompted to over-write the existing 2 existing files.  Click yes to both.  Click ok.  If you were not prompted to over-write existing files this may indicate that G2 was not installed in the default directory location. 

Maguire Products, Inc. HQ, 11 Crozerville Rd, Aston, PA 19014, USA
Phone: 610-459-4300; Phone 2: 888-459-2412 (North America); Fax: 610-459-2700;