| Time |
|
Description |
| 1:40 |
|
Controller
Overview |
| 7:40 |
|
Checkout
procedure
|
| 10:35 |
|
Setting
the model # |
| 12:40 |
|
Confirm
load cells work |
| 16:45 |
|
Controller
Description |
| 17:40 |
|
Setting
thumbwheel switches |
| 20:17 |
|
Keypad
description |
| 25:00 |
|
EXIT
key |
| 25:25 |
|
VIEW
running totals of all components blended |
| 28:50 |
|
RECIPE storage and
retrieval |
| 31:30 |
|
Locking out LED's |
| 32:40 |
|
Set BATCH weight to
fill barrel, box, etc. |
| 35:50 |
|
Set FAST mode to
increase blender throughput |
| 41:48 |
|
TAG reports with work
order#, operator#, recipe#, etc. |
| 45:25 |
|
Verify or lockout thumbwheel
switches |
| 49:35 |
|
OPERATE valve, alarm,
mixer, etc |
| 50:13 |
|
Test repeatability of valve
with TIME key |
| 50:13 |
|
Determine lag time with TIME
key |
| 54:00 |
|
Run CALIBRATION test |
| 55:30 |
|
Set ZERO and FULL weight |
| 59:50 |
|
PARAMETERS |
| 1:00:00 |
|
FLG: turn on RECIPE,
BATCH, FAST, and TAG keys |
| 1:01:20 |
|
RAL, NAL, CAL, AAL: set
alarm functions |
| 1:03:58 |
|
MIX: set mix time,
set jog time |
| 1:05:45 |
|
FCV: set flow control
valve delay time |
| 1:07:54 |
|
DTI: set weigh bin
dump time |
| 1:08:15 |
|
KDF: set sensitivity
of weight readings during calibration of load cells |
| 1:09:02 |
|
WDF: set sensitivity
of weight readings during normal operation |
| 1:11:45 |
|
BER: set emergency
bailout to avoid weigh bin overfill |
| 1:13:15 |
|
CXT, AXT: shift decimal
point on thumbwheel |
| 1:14:30 |
|
ROC: add color or
additive to regrind |
| 1:15:57 |
|
ROV: increase regrind
usage when excess regrind is available |
| 1:17:35 |
|
RHL: set high/low
level sensor in hopper |
| 1:18:20 |
|
FUL: set full weight
of bin |
| 1:18:30 |
|
MAX: set maximum
permissible weight in weigh bin |
| 1:18:47 |
|
TH/TL: set low and
high tare weights |
| 1:21:25 |
|
RSE, NSE, CSE, ASK: set
maximum limit for thumbwheel setting |
| 1:22:48 |
|
RLO: set low limit to
regrind setting |
| 1:23:00 |
|
DLY: set time mix
chamber sensor must be uncovered to start next cycle |
| 1:28:00 |
|
RLA, NLA, CLA, ALA:
set lag time |
| 1:28:33 |
|
PRC: set max percent
rate change forced by error correction routine |
| 1:27:05 |
|
STL: set settle time |
| 1:30:00 |
|
STAR FUNCTIONS |
| 1:30:55 |
|
*12: copy parameter
table from ROM to RAM |
| 1:31:45 |
|
*23: copy parameter
table from RAM to EEPROM |
| 1:32:10 |
|
*32: copy parameter
table from EEPROM to RAM |
| 1:33:10 |
|
*66: enter weigh
scale blender identification number |
| 1:33:45 |
|
*11: set USA/Europe date
format |
| 1:34:28 |
|
*89: set units - grams,
kilograms, ounces, pounds |
| 1:35:00 |
|
*77: print all
internal parameters |
| 1:35:12 |
|
*45: change password
for manual mode |
| 1:35:20 |
|
*78: change password
for program mode |
| 1:36:00 |
|
*25: reset ROM OK flag |
| 1:36:24 |
|
*88: print copy of
display to document weight readout |
| 1:37:08 |
|
*98: set flag for
continuous load cell raw signal readout |
| 1:37:42 |
|
*87: set flag for volumetric
operation |
| 1:39:04 |
|
*54: set flag to print
each cycle information |
| 1:40:03 |
|
*69: set flag to
treat regrind as a second natural |
| 1:41:47 |
|
ALARM FUNCTIONS |
| 1:42:46 |
|
PRINTER FUNCTIONS |
| 1:43:08 |
|
- print out every
cycle (*54) |
| 1:45:00 |
|
- print out totals
(grand total, interim total) |
| 1:46:53 |
|
- print out
internal parameters (*77) |
| 1:47:35 |
|
12 software |